Title of article :
Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators
Author/Authors :
Tanj M. Hurst، نويسنده , , Michael Hinrichs، نويسنده , , Christiane Breidenbach، نويسنده , , Norbert Katz، نويسنده , , Bernd Waldecker MD، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
7
From page :
402
To page :
408
Abstract :
OBJECTIVES The present study was designed to assess the extent of myocardial injury in patients undergoing transvenous implantation of an automatic implantable cardioverter-defibrillator (ICD) using cardiac troponin I (cTNI), which is highly specific marker of structural cardiac injury. BACKGROUND During ICD implantation, repetitive induction and termination of ventricular fibrillation (VF) vi endocardial direct current shocks is required to demonstrate the correct function of the device. Transthoracic electrical shocks can cause myocardial cell injury. METHODS Measurements of total creatine kinase (CK), CK-MB, myoglobin, cardiac troponin T (cTNT) and cTNI were obtained before and after ICD implantation in 49 consecutive patients. Blood samples were drawn before and 2, 4, 8, and 24 h after implantation. RESULTS Elevations of CK, CK-MB, myoglobin, cTNT and cTNI above cut-off level were found in 25%, 6%, 76%, 37% and 14% of patients, respectively, with peak cTNI concentrations ranging from 1.7 to 5.5 ng/ml. Cumulative defibrillation energy (DFE), mean DFE, cumulative VF time, number of shocks as well as prior myocardial infarction (MI) were found to be significantly related to rise of cTNI. Mean DFE ≥ 18 J and recent MI were identified as strong risk factors for cTNI rise. CONCLUSIONS During transvenous ICD implantation myocardial injury as assessed by cTNI rise occurs in about 14% of the patients. Peak cTNI concentrations are only minimally elevated reflecting subtle myocardial cell damage. Patients with recent MI and mean DFE ≥ 18 J seem to be prone to cTNI rise.
Keywords :
myocardial infarction , DFT , coronary artery disease , Cardiac troponin T , Creatine kinase , MI , CAD , ICD , DFE , CK , LVEF , left ventricular ejection fraction , implantable cardioverter-defibrillator , cTnI , cardiac troponin I , cTnT , VT/VF , ventricular tachycardia/ventricular fibrillation , defibrillation threshold , defibrillation energy
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
1999
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
481269
Link To Document :
بازگشت