Title of article :
Pleural adenosine deaminase in the separation of transudative and exudative pleural effusions
Author/Authors :
Figen Atalay، نويسنده , , Dilek Ernam، نويسنده , , H. Canan Hasanoglu، نويسنده , , Aysegul Karalezli، نويسنده , , ?zgül Kaplan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
5
From page :
1066
To page :
1070
Abstract :
Objective: The purpose of this study was to evaluate the usefulness of a new parameter, pleural adenosine deaminase (PADA), for separating transudative pleural effusion from exudative pleural effusion, and to compare the results with other tests (albumin gradient and protein gradient). Methods: From November 2001 to January 2003, 359 consecutive patients with pleural effusion who underwent a diagnostic thoracentesis were included in the study. Effusions were individually classified as transudates or exudates after the careful evaluation of all clinical data and biochemical parameters of pleural fluid and serum of patients on the basis of Lightʹs criteria. The means and standard deviations of PADA, pleural/serum ADA (P/S ADA) ratio, albumin gradient and protein gradient were evaluated for transudative and exudative effusions. The best cut-off values for each test were identified by using the receiver operating characteristic (ROC) curve. The optimum cut-off level was determined by selecting points of test values that provided the greatest sum of sensitivity and specificity. Results: There were 113 transudates and 246 exudates. For each test, differences in mean value between the transudate group and the exudate group were statistically significant (t test, P < 0.001). The optimum cut-off levels for PADA and P/S ADA were 15.3 U/L and 0.66 U/L, respectively. ROC analysis confirmed previous recommendations for albumin gradient (12 g/L) and protein gradient (31 g/L). For detecting exudates, the PADA test yielded a sensitivity and specificity of 85.8% and 82.3%, respectively. Sensitivity and specificity of the albumin gradient were found to be 88.5% and 79.3%, and of the protein gradient 85% and 83.2%, respectively. The areas under the curve (AUC) data and accuracy demonstrated similar discriminative properties in the examined tests. Conclusions: The measurement of PADA is suggested as a reliable test in the separation of pleural exudates from transudates with accuracy similar to that of the albumin gradient and protein gradient.
Keywords :
Pleural effusion , Adenosine deaminase (ADA) , Transudates
Journal title :
Clinical Biochemistry
Serial Year :
2005
Journal title :
Clinical Biochemistry
Record number :
484662
Link To Document :
بازگشت