Title of article :
Graphical presentation of the range of hip and knee rotations for clinical evaluation of gait
Author/Authors :
Pei Lai Cheng، نويسنده , , Mark Pearcy، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
3
From page :
84
To page :
86
Abstract :
Objective. This paper reports a method of using a multi-axis graph to represent the range of rotations at the hip and knee joints during gait for clinical evaluation of a patientʹs performance. Design and methods. The multi-axis graph uses 12 symmetrically arranged axes to represent each component of range of rotations at the hip and knee joints of both legs. The range of joint rotations of thirteen normal subjects and two patients were measured using an electromagnetic motion tracking system with four foot switches. Results. The range of joint rotations of normal subjects shows a symmetrical star in the multi-axis graph. Abnormal function of a patient shows an asymmetrical star. Conclusions. This representation provides a simple way to examine a patientʹs performance in a time effective manner.
Keywords :
range of motion , biomechanics , Gait analysis , Joint rotation , Hip and knee joints
Journal title :
Clinical Biomechanics
Serial Year :
2001
Journal title :
Clinical Biomechanics
Record number :
485895
Link To Document :
بازگشت