Title of article :
Biomechanical performance of the new BeadEx implant in the treatment of osteoporotic vertebral body compression fractures: Restoration and maintenance of height and stability
Author/Authors :
A. Kettler، نويسنده , , W. Schmoelz، نويسنده , , Y. Shezifi، نويسنده , , N. Ohana، نويسنده , , A. Ben-Arye، نويسنده , , L. Claes، نويسنده , , H.-J. Wilke، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
7
From page :
676
To page :
682
Abstract :
Background Vertebral compression fractures are counted among the most common complications of osteoporosis. For treatment, a new, alternative implant has been developed (BeadEx, Expandis, Hof HaCarmel, Israel). The aim of the present in vitro study was to evaluate whether this implant is able to restore the initial height and three-dimensional stability after fracture and whether it is able to maintain this height and stability during complex cyclic loading. Methods The BeadEx implant consists of small titanium rolls, which are pressed into the vertebral body through specially designed, hollow pedicle screws. The height and the three-dimensional flexibility of 18 bisegmental spine specimens (nine T12–L2, nine L3–L5) was measured, first, before and after creating a wedge compression fracture at the middle vertebral body (L1 resp. L4), second, after treatment of the fracture, and, third, during and after complex cyclic loading. The fractures were treated either with BeadEx plus internal fixator, BeadEx plus bone cement or vertebroplasty for comparison. Findings The height before fracture could almost be restored by BeadEx plus bone cement but not by BeadEx plus fixator and vertebroplasty. The total height loss after cyclic loading was smallest with BeadEx plus bone cement (in median −4.7 mm with respect to the intact specimens) but −6.2 mm with BeadEx plus fixator and −7.8 mm with vertebroplasty. The three-dimensional stability of the specimens was clearly higher if treated with BeadEx plus fixator than with BeadEx plus bone cement or vertebroplasty. Interpretation From a biomechanical point of view, BeadEx plus bone cement can be recommended as an alternative to vertebroplasty in the treatment of osteoporotic vertebral body fractures. BeadEx plus fixator can be recommended if additional stability is needed.
Keywords :
Spine , Fracture , Surgical treatment , biomechanics , Cyclic loading
Journal title :
Clinical Biomechanics
Serial Year :
2006
Journal title :
Clinical Biomechanics
Record number :
486608
Link To Document :
بازگشت