• Title of article

    Automatic alignment of infrared video frames for equipment leak detection

  • Author/Authors

    Zhou، Liming نويسنده , , Zeng، Yousheng نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    -222
  • From page
    223
  • To page
    0
  • Abstract
    Petroleum refining and petrochemical industries start using infrared (IR) cameras to detect volatile organic compounds (VOC) leaking out of process equipment. However, further quantitative processing of these video image data or automatic recognition of VOC plumes are hindered by unaligned video frames owing to the slight vibrations of the camera. An automatic method is developed to align the IR video frames as a preprocessing procedure for other possible video processing methods. The alignment method is based on a twodimensional spatial Fourier transform. The accuracy can reach fractional pixels in estimation of translational shift and 1–2° for rotational shift. Temporal Fourier transform of actual industrial tests of IR videos is performed with both unaligned and aligned video frames. The results indicate that only after the alignment of the video frames, the camera motion interferences on VOC plume identification can be eliminated or minimized, and the VOC plume can be identified through investigating the characteristic flickering frequency power in the temporal Fourier transform. This alignment method provides a useful tool for IR or other optical video image data preprocessing purposes.
  • Journal title
    Analytica Chimica Acta
  • Serial Year
    2007
  • Journal title
    Analytica Chimica Acta
  • Record number

    49019