• Title of article

    Prophylactic plating of the donor site of osteocutaneous radial forearm flaps

  • Author/Authors

    V. A. Nunez، نويسنده , , Kevin J. Pike، نويسنده , , G. C. Avery، نويسنده , , J. W. Rosson، نويسنده , , P. Johnson، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    3
  • From page
    210
  • To page
    212
  • Abstract
    We carried out a retrospective study of fracture morbidity of radial forearm osteocutaneous donor sites. During a period of three-and-a-half years, 12 patients had had composite flaps taken, and 5 of them had subsequently fractured the radius. We then elected to plate the radius prophylactically and found that over a period of just over two years, none of the 8 patients who had had prophylactic plating at the original harvesting operation had subsequently fractured the radius.
  • Journal title
    British Journal of Oral and Maxillofacial surgery
  • Serial Year
    1999
  • Journal title
    British Journal of Oral and Maxillofacial surgery
  • Record number

    492539