Title of article :
Selected characteristics of an Ormocer and a conventional hybrid resin composite
Author/Authors :
Dilek Arslantunali Tagtekin، نويسنده , , Funda Caliskan Yanikoglu، نويسنده , , Funda Ozturk Bozkurt، نويسنده , , Burcu Kologlu، نويسنده , , Haydar Sur، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
11
From page :
487
To page :
497
Abstract :
Objectives. The objective of this in vitro study was to evaluate surface roughness, hardness and wear resistance of an Ormocer (Admira), polymerized by a plasma arc system. A secondary objective was to investigate two placement technique bulk or incremental layers. Methods. Blocks from Admira and Amelogen (a microhybrid composite) were prepared in cylinders, 3 mm in diameter, and 2 and 5 mm in thickness (bulk or incrementally placed) and polymerized by a plasma arc and a conventional light system. Surface roughness measurements were taken by a Surface Profilometer on the top of the specimens. Vickers hardness measurements, with a load of 600 mN were taken on the top and bottom of 2 mm and top, intermediate and bottom of 5 mm thick specimens. For the wear test, specimes (8 mm in diameter and 2 mm in thickness) of Admira, Amelogen and amalgam were tested in a ball-on design, by circular movements of the antagonist (alumina ball; diameter 10 mm) under 10 N load. For the statistical evaluation of the results of surface roughness, microhardness and wear test; a paired samples t-test and Kruskal-Wallis analysis of variance test, were performed. Results. Admira showed highest hardness values in all polymerization types at the top surface and this was statistically significant (p<0.05). These highest hardness values were obtained with conventional polymerization (81.84±1.167 VHN). Meanwhile, the wear resistance of Admira was found to be higher than Amelogen (Wdadmira=0.024±0.00149 mm3; Wdamelogen=0.032±0.00075 mm3). However, Admira demonstrated the highest surface roughness value compared to Amelogen, with plasma arc 5 s (0.65±0.023 μm). Amelogen was found to have the lowest surface roughness value with conventional 40 s (0.45±0.012 μm). Significance. The results indicated that Ormocer, which was developed by Ormocer technology, demonstrated higher microhardness and wear resistance when compared to a hybrid composite; however, the polishability of Ormocer needs further investigation. Also the selection of visible light activated composite resins exhibited higher surface microhardness values when polymerized with conventional rather than with plasma arc.
Keywords :
Microhardness , Wear , Bulk placement , ORMOCER , Plasma arc , surface roughness
Journal title :
Dental Materials
Serial Year :
2004
Journal title :
Dental Materials
Record number :
505840
Link To Document :
بازگشت