Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis
Author/Authors :
Fernando Zarone، نويسنده , , Roberto Sorrentino، نويسنده , , Tonino Traini، نويسنده , , Donato Di lorio، نويسنده , , Sergio Caputi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
Objectives
The present in vitro study aimed at evaluating the fracture resistance of both implant-supported screw- and cement-retained porcelain fused to metal (PFM) single crowns. A scanning electron microscope (SEM) evaluation of the mode of failure of the specimens was also performed.
Methods
Forty PFM premolar-shaped identical single crowns were realized. The restorations were divided into two groups: cement-retained (group 1) and screw-retained (group 2) prostheses. Compressive loading tests and SEM fractographic analyses were performed. The data were statistically analysed by means of the Studentʹs t-test, with a confidence interval of 95%.
Results
The mean fracture load value was 1657 (±725) N in group 1 and 1281 (±747) N in group 2; the statistical analysis pointed out no significant differences between the two groups (p = 0.115). The mean work at maximum load value was 0.775 (±0.619) J in group 1 and 0.605 (±0.526) J in group 2; the statistical analysis pointed out no significant differences between the two groups (p = 0.355).
All the samples were affected by cohesive fractures of the porcelain. Screw-retained crowns showed microcracks at the level of the occlusal access to the screw and extensive fractures in the whole thickness of the ceramics. On the contrary, cement-retained restorations were affected by less wide paramarginal fractures of the porcelain.
Significance
A stronger implant-prosthetic connection was noticed in cemented restorations group than in screw-retained single crowns. Even though negatively influenced by the presence of the occlusal access to the screw, the metal–ceramics bond can be considered predictable in both the implant-prosthetic connection systems analysed.
Keywords :
Fracture , Cement-retained , Screw-retained , Implant-supported prostheses , Single crown , Porcelain fused to metal , Resistance