Title of article
Cuspal movement and microleakage in premolar teeth restored with resin-based filling materials cured using a ‘soft-start’ polymerisation protocol
Author/Authors
G.J.P. Fleming، نويسنده , , R.R. Cara، نويسنده , , W.M. Palin، نويسنده , , F.J.T. Burke، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
7
From page
637
To page
643
Abstract
Objectives
To investigate the effect of polymerisation shrinkage strain of four posterior filling materials on cuspal movement, degree of conversion (DC) and cervical gingival microleakage of mesio-occlusal-distal (MOD) restorations placed incrementally in maxillary premolar teeth using a ‘soft-start’ polymerisation protocol.
Methods
Forty sound extracted upper premolar teeth were subjected to standardised preparation of a large MOD cavity before restoration. A ‘soft-start’ polymerisation curing regimen was used and each posterior filling material was placed in eight increments with the appropriate bonding system. A twin channel deflection measuring gauge allowed a measurement of individual cusp deflections at each stage of polymerisation. Restored teeth were thermocycled before immersion in a 0.2% basic fuchsin dye for 24 h. After sagittal sectioning of the restored teeth in a mesio-distal plane, the sectioned restorations were examined to assess cervical microleakage. The DC was also assessed using a diffuse-reflectance accessory on a Fourier transform infra-red spectrophotometer.
Results
A significant increase in cuspal movement recorded for Z100 (20.06 ± 4.71) compared with Filtek Z250™ (16.52 ± 3.26), P60 (14.23 ± 3.71) and Admira (11.11 ± 2.47). No significant reduction in cuspal movement was identified when compared with a previous study [6] where a full-intensity standard polymerisation protocol was employed. No significant differences were also identified between the materials when the cervical gingival microleakage scores or DC were examined for the ‘soft-start’ compared with the standard polymerisation protocol.
Conclusions
Although material type remained a significant factor, the use of a ‘soft-start’ polymerization compared with a standard curing regime did not offer any significant reduction in associated cuspal movement, DC or gingival microleakage at the cervical dentine cavosurface margin of the cavities restored with the resin-based filling materials.
Keywords
Soft-start polymerisation , Resin-based composite , Cuspal movement , Gingival microleakage , ORMOCER