Title of article :
Microstructural studies of 35 °C Copper Ni–Ti orthodontic wire and TEM confirmation of low-temperature martensite transformation
Author/Authors :
William A. Brantley، نويسنده , , Wenhua Guo، نويسنده , , William A.T. Clark، نويسنده , , Masahiro Iijima، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
7
From page :
204
To page :
210
Abstract :
Background Previous temperature-modulated differential scanning calorimetry (TMDSC) study of nickel–titanium orthodontic wires revealed a large exothermic low-temperature peak that was attributed to transformation within martensitic NiTi. Purpose The purpose of this study was to use transmission electron microscopy (TEM) to verify this phase transformation in a clinically popular nickel–titanium wire, identify its mechanism and confirm other phase transformations found by TMDSC, and to provide detailed information about the microstructure of this wire. Methods The 35 °C Copper nickel–titanium wire (Ormco) with cross-section dimensions of 0.016 in. × 0.022 in. used in the earlier TMDSC investigation was selected. Foils were prepared for TEM analyses by mechanical grinding, polishing, dimpling, ion milling and plasma cleaning. Standard bright-field and dark-field TEM images were obtained, along with convergent-beam electron diffraction patterns. A cryo-stage with the electron microscope (Phillips CM 200) permitted the specimen to be observed at −187, −45, and 50 °C, as well as at room temperature. Microstructures were also observed with an optical microscope and a scanning electron microscope. Results Room temperature microstructures had randomly oriented, elongated grains that were twinned. Electron diffraction patterns confirmed that phase transformations took place over temperature ranges previously found by TMDSC. TEM observations revealed a high dislocation density and fine-scale oxide particles, and that twinning is the mechanism for the low-temperature transformation in martensitic NiTi. Conclusions TEM confirmed the low-temperature peak and other phase transformations observed by TMDSC, and revealed that twinning in martensite is the mechanism for the low-temperature peak. The high dislocation density and fine-scale oxide particles in the microstructure are the result of the wire manufacturing process.
Keywords :
Nickel–Titanium , Orthodontic wires , TRANSMISSION ELECTRON MICROSCOPY , Structure , Dislocations , Metallurgical phases
Journal title :
Dental Materials
Serial Year :
2008
Journal title :
Dental Materials
Record number :
506435
Link To Document :
بازگشت