Title of article :
The ball mill as a means of investigating the mechanical failure of dental materials
Author/Authors :
N. H. Abu Kasim، نويسنده , , D. T. Millett، نويسنده , , J. F. McCabe، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
8
From page :
117
To page :
124
Abstract :
Objective: The main purpose of this paper is to present a new method of predicting clinical performance using mechanical loading in a ball mill. Methods: A series of four experiments (two involving a hybrid composite and one each on orthodontic brackets and bands) is described in which the ball mill was used to subject specimens to mechanical fatigue. Results: A reproducibility study using composite beam specimens showed no significant difference between the Mean Survival Time (MST) in all the three experimental runs (P = 0.42). When subjected to thermal cycling, the MST of the cycled group was 155.0 min compared to 247.0 min for the control group (P < 0.01). The MST of untreated and sandblasted brackets was 7.9 h and 14 h respectively (P < 0.01). There is also a significant difference (P < 0.001) in the MST of sandblasted bands when compared to the untreated bands. Conclusions: The ball mill proved to be a convenient and reproducible means of producing mechanical fatigue and may be useful in predicting the clinical performance of dental materials.
Keywords :
Fatigue , Composites , orthodontics , ball mill
Journal title :
Journal of Dentistry
Serial Year :
1996
Journal title :
Journal of Dentistry
Record number :
506709
Link To Document :
بازگشت