Title of article
The repeatability of human dentine permeability measurement in vitro
Author/Authors
Taher O. Elgalaid، نويسنده , , Steve L. Creanor، نويسنده , , Siobhan Creanor، نويسنده , , Andrew F. Hall، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
7
From page
42
To page
48
Abstract
Objective
The aim of this study was to determine the repeatability of apparatus designed to assess dentine permeability at two different pressures.
Method
Forty-five human coronal tooth portions were prepared and permeability was measured at two separate time points, 5 h apart, at 14 cm H2O pressure and then at 100 cm H2O pressure. Repeatability was determined using the limits of agreement (LOA) method.
Results
The results showed equal mean permeability of 0.6 μl at both time 1 and time 2 at 14 cm H2O pressure, and 2.7 and 2.5 μl at time 1 and time 2, respectively, at 100 cm H2O pressure. At 14 cm H2O pressure, the LOA were (−0.4, 0.4) μl and at 100 cm H2O pressure the LOA were (−0.2, 0.6) μl.
Conclusion
Although repeatability measurement at 14 cm H2O pressure appeared to be acceptable, the higher permeability values at 100 cm H2O pressure may make the latter the pressure of choice despite the small bias.
Keywords
Dentinal tubulesDentine permeabilityRepeatabilityWater pressure
Journal title
Journal of Dentistry
Serial Year
2008
Journal title
Journal of Dentistry
Record number
507727