Title of article :
Clinical experience with Günther temporary inferior vena cava filters
Author/Authors :
Ioannis S. Kaskarelis، نويسنده , , Maria Koukoulaki، نويسنده , , Chrysanthi E. Chlapoutaki، نويسنده , , Dimitris E. Skarpalezos، نويسنده , , Asimina D. Baltouka، نويسنده , , Theodoros K. Vagdatlis، نويسنده , , Vasiliki A. Androutsopoulou، نويسنده , , Ion Bellenis، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
108
To page :
113
Abstract :
This retrospective study was performed to evaluate the safety and effectiveness of Günther temporary inferior vena cava (IVC) filters. Fifteen Günther temporary filters were placed in 13 patients because of deep vein thrombosis (DVT) with pulmonary embolism (PE) despite DVT prophylaxis (9/13) or temporary contraindications for anticoagulants as well as recent or pending surgery (4/13). No clinical manifestation of PE was observed during the filtration or during the removal. Günther temporary IVC filters are easy and safe to use, and are effective in clot trapping, protecting patients at high risk for PE in whom anticoagulation treatment failed or is contraindicated.
Keywords :
pulmonary embolism , Vena cava filter , Gqnther temporary filter , interventional procedure
Journal title :
Clinical Imaging
Serial Year :
2006
Journal title :
Clinical Imaging
Record number :
508944
Link To Document :
بازگشت