Title of article :
Separation of contamination caused by coil clicks from responses elicited by transcranial magnetic stimulation
Author/Authors :
Hannu Tiitinen، نويسنده , , Juha Virtanen، نويسنده , , Risto J. Ilmoniemi، نويسنده , , Janne Kamppuri، نويسنده , , Marko Ollikainen، نويسنده , , Jarmo Ruohonen، نويسنده , , Risto N??t?nen، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1999
Pages :
4
From page :
982
To page :
985
Abstract :
Transcranial magnetic stimulation (TMS) is accompanied with loud clicks that evoke auditory responses in the brain, confounding several types of TMS studies. We investigated the effects of these clicks with high-resolution EEG by applying TMS pulses at 3 magnitudes, with the coil placed either at 10 or 50 mm over the subjects’ vertex and recording event-related potentials (ERPs). The clicks were found to elicit a positively displaced response at 150–250 ms post-TMS. Furthermore, clicks were found to interact with simultaneously presented auditory sinewave stimuli, resulting in an amplitude decrease in the auditory N1 response.
Keywords :
Transcranial magnetic stimulation , Auditory , electroencephalogram , EEG , Event-related potential , ERP , Transcranial magnetic stimulation
Journal title :
Clinical Neurophysiology
Serial Year :
1999
Journal title :
Clinical Neurophysiology
Record number :
521656
Link To Document :
بازگشت