Abstract :
Objectives: To evaluate the stimulation effectiveness of different magnetic stimulator devices with respect to pulse waveform and current direction in the motor cortex. Methods: In 8 normal subjects we determined motor thresholds of transcranial magnetic stimulation in a small hand muscle. We used focal figure-of-eight coils of 3 common stimulators (Dantec Magpro, Magstim 200 and Magstim Rapid) and systematically varied current direction (postero-anterior versus antero-posterior, perpendicular to the central sulcus) as well as pulse waveform (monophasic versus biphasic). The coil position was kept constant with a stereotactic positioning device. Results: Motor thresholds varied consistently with changing stimulus parameters, despite substantial interindividual variability. By normalizing the values with respect to the square root of the energy of the capacitors in the different stimulators, we found a homogeneous pattern of threshold variations. The normalized Magstim threshold values were consistently higher than the normalized Dantec thresholds by a factor of 1.3. For both stimulator types the monophasic pulse was more effective if the current passed the motor cortex in a postero-anterior direction rather than antero-posterior. In contrast, the biphasic pulse was weaker with the first upstroke in the postero-anterior direction. We calculated mean factors for transforming the intensity values of a particular configuration into that of another configuration by normalizing the different threshold values of each individual subject to his lowest threshold value. Conclusions: Our transformation factors allow us to compare stimulation intensities from studies using different devices and pulse forms. The effectiveness of stimulation as a function of waveform and current direction follows the same pattern as in a peripheral nerve preparation (J Physiol (Lond) 513 (1998) 571).
Keywords :
Human motor cortex , Thresholds , Current direction , Transformation factors , Stimulation effectiveness , Pulse waveform
Journal title :
Clinical Neurophysiology
Serial Year :
2001
Journal title :
Clinical Neurophysiology
Record number :
522107
Link To Document :
بازگشت