Title of article
Interobserver variation in the interpretation of SSEPs in anoxic–ischaemic coma
Author/Authors
E.G.J. Zandbergen، نويسنده , , A. Hijdra، نويسنده , , R.J. de Haan، نويسنده , , J.G. van Dijk، نويسنده , , B.W. Ongerboer de Visser، نويسنده , , F. Spaans، نويسنده , , D.L.J. Tavy، نويسنده , , J.H.T.M. Koelman، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
7
From page
1529
To page
1535
Abstract
Objective
To study interobserver variation in the interpretation of median nerve SSEPs in patients with anoxic–ischaemic coma.
Methods
SSEPs of 56 consecutive patients with anoxic–ischaemic coma were interpreted independently by 5 experienced clinical neurophysiologists using guidelines derived from a pilot study. Interobserver agreement was expressed as kappa coefficients.
Results
Kappa ranged from 0.20 to 0.65 (mean 0.52, SD 0.14). Disagreement was related with noise level and failure to adhere strictly to the guidelines in 15 cases. The presence or absence of N13 and cortical peaks caused disagreement in 5 cases each. For recordings with a noise level of 0.25 μV or more, mean kappa was 0.34; for recordings with a noise level below 0.25 μV mean kappa was 0.74.
Conclusions
Interobserver agreement for SSEPs in anoxic–ischaemic coma was only moderate. Since the noise level strongly influenced interobserver variation, utmost attention should be given to its reduction. If an artefact level over 0.25 μV remains, absence of N20 cannot be judged with sufficient certainty and the SSEP should be repeated at a later stage.
Significance
Because of its moderate interobserver agreement, great care has to be given to accurate recording and interpretation of SSEPs before using the recordings for non-treatment decisions.
Keywords
Cerebral anoxia , Somatosensory evoked potentials , Interobserver variation , coma