Title of article :
The long thoracic nerve conduction study revisited in 2006
Author/Authors :
P. Seror، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
5
From page :
2446
To page :
2450
Abstract :
Objective To compare the reliability and feasibility of recording long thoracic nerve (LTN) conductions either with surface or needle electrodes. Methods The nerve conduction studies were carried out bilaterally on 40 control subjects. The LTN was first stimulated at the axilla and recorded with surface electrodes located on the 7th or 8th digitations of the serratus anterior (SA), then stimulated at Erb’s point and recorded with a needle inserted in the 6th or 7th digitations of the SA. For each method, the latency and amplitude of the motor action potential were recorded. Results Responses were recorded on both sides for each patient. With surface recording, the mean latency was 2.2 ± 0.30 ms, and the mean amplitude was 5.3 ± 2.4 mV. With needle recording, the mean latency was 3.65 ± 0.45 ms, and the mean amplitude was 8.95 ± 4 mV. Conclusions This study demonstrates that both techniques are reliable, feasible, and correlate well. Significance Our study shows surface recording of nerve conduction should be favored because it is non-traumatic, less uncomfortable for the patient, and less prone to pitfalls. Nevertheless, in pathological cases, both techniques should be used at initial and follow-up examinations in order to better assess axonal loss and nerve conduction impairment.
Keywords :
Long thoracic nerve , Serratus anterior muscle , Nerve compression , Parsonage and Turner syndrome , electrodiagnosis , Nerve conduction
Journal title :
Clinical Neurophysiology
Serial Year :
2006
Journal title :
Clinical Neurophysiology
Record number :
523716
Link To Document :
بازگشت