• Title of article

    Organophosphorus Hydrolase-Based Assay for Organophosphate Pesticides

  • Author/Authors

    Rogers، K. R. نويسنده , , Wang، Y. نويسنده , , Mulchandani، A. نويسنده , , Mulchandani، P. نويسنده , , Chen، W. نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    -516
  • From page
    517
  • To page
    0
  • Abstract
    We report a rapid and versatile organophosphorus hydrolase (OPH)-based method for measurement oforganophosphates. This assay is based on a substrate-dependent change in pH at the local vicinity of the enzyme. The pH change is monitored using fluorescein isothiocyanate (FITC), which is covalently immobilized to the enzyme. This method employs the use ofpoly(methyl methacrylate) beads to which the FITC-labeled enzyme is adsorbed. Analytes were then measured using a microbead fluorescence analyzer. The dynamic concentration range for the assay extends from 25 to 400 (mu)M for paraoxon with a detection limit of 8(mu)M. Organophosphorus insecticides measured using this technique included ethylparathion, methylparathion, dursban, fensulfothion, crotoxyphos, diazinon, mevinphos, dichlorvos, and coumaphos. This technique was used to measure coumaphos in biodegradation samples of cattle dip wastes and showed a high correlation (r^-2 = 0.998) to an HPLC method.
  • Keywords
    Clear Sky , Lighting , Daylight factor
  • Journal title
    BIOTECHNOLOGY PROGRESS
  • Serial Year
    1999
  • Journal title
    BIOTECHNOLOGY PROGRESS
  • Record number