Title of article :
Biphasic Transthoracic Defibrillation Causes Fewer ECG ST-Segment Changes After Shock, , ,
Author/Authors :
Ramakota K. Reddy، نويسنده , , Marye J. Gleva، نويسنده , , Bradford E Gliner، نويسنده , , G. Lee Dolack، نويسنده , , Peter J. Kudenchuk and DAVID Investigators، نويسنده , , Jeanne E. Poole، نويسنده , , Gust H Bardy، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
8
From page :
127
To page :
134
Abstract :
Study objective: Electrocardiographic abnormalities are common after transthoracic defibrillation. ECG ST-segment changes are especially problematic after defibrillation and may indicate ischemic or shock-induced cardiac dysfunction after resuscitation. Biphasic defibrillation waveforms, compared with monophasic waveforms, diminish shock-induced cardiac dysfunction in laboratory preparations. This effect has not been validated in human subjects. We therefore evaluated in a prospective, blinded fashion the effect of biphasic and monophasic transthoracic defibrillation on the ECG ST segment in 30 consecutive patients during surgery for the implantation of a cardioverter-defibrillator. Methods: In each patient two low-energy truncated biphasic transthoracic defibrillation shocks (115 and 130 J) were compared with a standard clinical 200 J monophasic damped–sine wave shock. The biphasic shocks and the damped–sine wave shock have been demonstrated to have equal defibrillation efficacy of 97%. Fifteen-second ECG signals recorded across transthoracic defibrillation electrodes were digitized before ventricular fibrillation induction and immediately after each defibrillation attempt. The ST segments 80 msec after the J point were analyzed in a blinded fashion by two reviewers. The ST-segment deflection, QRS-interval duration, QT interval, and heart rate after each therapy were compared with baseline values. Results: ECG ST-segment elevation was significantly greater with the 200-J damped-sine waveform than with either biphasic waveform. The ECG ST-segment levels were –.55±.36 at baseline, –.76±.36 mm after internal shock, –.02–.36 mm after 115-J biphasic shock, .21±.38 mm after 130-J biphasic shock, and 2.09±.37 mm after 200-J damped–sine wave shock (P<.0001). QRS-interval duration, QT interval, and heart rate did not change significantly with any waveform. Conclusion: Transthoracic defibrillation with biphasic waveforms results in less postshock ECG evidence of myocardial dysfunction (injury or ischemia) than standard monophasic damped sine waveforms without compromise of defibrillation efficacy. [Reddy RK, Gleva MJ, Gliner BE, Dolack GL, Kudenchuk PJ, Poole JE, Bardy GH: Biphasic transthoracic defibrillation causes fewer ECG ST-segment changes after shock. Ann Emerg Med August 1997;30:127-134.]
Journal title :
Annals of Emergency Medicine
Serial Year :
1997
Journal title :
Annals of Emergency Medicine
Record number :
535838
Link To Document :
بازگشت