• Title of article

    One year of experience with alanine dosimetry in radiotherapy

  • Author/Authors

    B. Schaeken، نويسنده , , P. Scalliet، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    6
  • From page
    1177
  • To page
    1182
  • Abstract
    Commercially available alanine dosimeters from different manufacturers were purchased for this study. The response of the detectors was evaluated with 60Co gamma radiation in the dose range 0.2–200 Gy, using a small EPR spectrometer dedicated to dosimetry. The batch sensitivity, inter-specimen scattering and background signal for the different selection of dosimeters were evaluated. The usefulness of the alanine dosimetry system for clinical routine is illustrated by in vivo measurements during 192Ir brachytherapy of cervix carcinoma.
  • Journal title
    Applied Radiation and Isotopes
  • Serial Year
    1996
  • Journal title
    Applied Radiation and Isotopes
  • Record number

    539618