Title of article :
ESR dosimetry of a deceased radiation worker
Author/Authors :
M. Ikeya، نويسنده , , H. Sumitomo، نويسنده , , C. Yamanaka، نويسنده , , D. C. Lloyd، نويسنده , , A. A. Edwards، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
4
From page :
1341
To page :
1344
Abstract :
A case of overexposure of an industrial radiographer using 192Ir sources and having a filmbadge dosimeter record of 104 mSv has been examined with ESR dosimetry of postmortem tooth and bone specimens. ESR measurements of the tooth enamel showed an intense signal of CO2− and gave the equivalent dose (ED) of 14 Gy by the additive dose method using γ-rays from a source of 60Co. The doses for a finger bone and humerus were 14.7 and 7.0 Gy, respectively. It was concluded that he had been exposed to radiation repeatedly over 10 yr and that ESR dosimetry can give a life-long cumulative dose for personnel using radiation.
Journal title :
Applied Radiation and Isotopes
Serial Year :
1996
Journal title :
Applied Radiation and Isotopes
Record number :
539646
Link To Document :
بازگشت