• Title of article

    The use of associated particle timing based on the D + D reaction for elemental analysis of bulk samples such as the human body

  • Author/Authors

    C. J. Evans، نويسنده , , G. C. Pet?، نويسنده , , S. Al-Lehyani، نويسنده , , J. B. Darko، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    10
  • From page
    257
  • To page
    266
  • Abstract
    The use of associated particle timing based on the D + D reaction has been demonstrated for elemental analysis of bulk samples such as the human body. The neutron energy of 2.8 MeV eliminates the background from organic matrices. The nanosecond timing of a HPGe detector renders it possible to identify the spatial origin of the measured γ radiation limiting the sensitive are to a single pixel. By this technique the background could be reduced by a factor of ≥ 1000, but the present set-up has achieved an effective factor only in the range 20–100, due to losses in the generation of timing signals. The very clean γ-spectra obtained permit the use of high efficiency scintillation detectors. Sensitivities for measuring Al, Ti, and Fe are presented at an extrapolated dose of 10 mSv.
  • Journal title
    Applied Radiation and Isotopes
  • Serial Year
    1997
  • Journal title
    Applied Radiation and Isotopes
  • Record number