Title of article :
Low-resolution gamma-ray measurements of process hold-up
Author/Authors :
J. K. Sprinkle Jr.، نويسنده , , R. Cole، نويسنده , , M. L. Collins، نويسنده , , S. -T. Hsue، نويسنده , , P. A. Russo، نويسنده , , R. Siebelist، نويسنده , , H. A. Smith Jr.، نويسنده , , R. N. Ceo، نويسنده , , S. E. Smith، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Pages :
6
From page :
1529
To page :
1534
Abstract :
This tool, consisting of software with a compact detector, an M3CA, and an Intermec datalogger: 1. 1. acquires and manages several hundred spectra in an hour; 2. 2. produces prompt and reliable quantitative analyses; 3. 3. is self-powered, easily carried and operated by a single user; 4. 4. accomodates varying degrees of user expertise; 5. 5. corrects for the effects of equipment geometry; 6. 6. corrects for the effects of equipment attenuation; 7. 7. tolerates facility variables such as temperature fluctuations and equipment accessibility; 8. 8. has been subjected to quality testing under field conditions; and 9. 9. does not require extensive specialized training for the operators.
Journal title :
Applied Radiation and Isotopes
Serial Year :
1997
Journal title :
Applied Radiation and Isotopes
Record number :
539940
Link To Document :
بازگشت