Title of article
Manufacture of strontium-82/rubidium-82 generators and quality control of rubidium-82 chloride for myocardial perfusion imaging in patients using positron emission tomography
Author/Authors
Teresa M. Alvarez-Diez، نويسنده , , Robert deKemp، نويسنده , , Robert Beanlands، نويسنده , , John Vincent and EPHESUS Investigators، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
9
From page
1015
To page
1023
Abstract
We describe a protocol to manufacture 82Sr/82Rb generators and 82RbCl for myocardial imaging with PET. The generators are manufactured in 3 stages: (1) preparation of a tin oxide column, (2) leak test of the generator column and (3) loading of the generator with 82Sr. The generators produced sterile and non-pyrogenic 82RbCl for i.v. injection. No significant 82Sr/85Sr breakthroughs were observed after elution with 20 l of saline. The automated system delivered human doses of 82RbCl accurately.
Keywords
strontium 82 , Coronary Artery Disease , heart muscle perfusion , rubidium 82 , positron emission tomography
Journal title
Applied Radiation and Isotopes
Serial Year
1999
Journal title
Applied Radiation and Isotopes
Record number
540401
Link To Document