Title of article
Transferability of ASTM/NIST alanine–polyethylene recipe at ISS
Author/Authors
C. De Angelis، نويسنده , , P. Fattibene، نويسنده , , S. Onori، نويسنده , , E. Petetti، نويسنده , , A. Bartolotta، نويسنده , , A. Sansone Santamaria، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
5
From page
1197
To page
1201
Abstract
Alanine–polyethylene solid state dosimeters were prepared at Istituto Superiore di Sanità (ISS) following the recipe proposed by National Institute of Standards and Technology (NIST) with the goal of testing its transferability. Dosimeters were prepared using 95% alanine and 5% polyethylene, by weight. They are rugged and of increased sensitivity, repeatability and reproducibility as respect to the ISS alanine-paraffin pellets. Reproducibility of about 1% was obtained at 10 Gy and at 3 Gy if one single pellet or a stack of five dosimeters were used, respectively.
Journal title
Applied Radiation and Isotopes
Serial Year
2000
Journal title
Applied Radiation and Isotopes
Record number
540679
Link To Document