Abstract :
Photon activation of indium foils is proposed as a dosimetry technique for high dose rate measurements in a 60Co irradiation facility. The irradiated indium nuclei may be raised to its metastable isomers of 113mIn and 115mIn. The isomer 115mIn, with appreciable induced radioactivity, was selected for dose-rate measurements. Based on the photon flux distribution and the derived dose rates, which were simulated by the MCNP code, the dependence of dose rate measurement sensitivity of indium foils with respect to photon energy at various irradiation distances is described. For practical uses, the radioactivity of 115mIn was linearly related to the dose rate response at the specified irradiation positions. By comparing with a calibrated dosimetry system, the measurement deviation of the indium dosimeter, over dose rates ranging from 10 to 104 Gy/h, was evaluated and exhibited an uncertainty of ±7%. Other related characteristics including measurement sensitivity and range, linearity with respect to the variation of dose rate, and limitations of the indium dosimeter were evaluated to justify it as an alternative for monitoring dose rate in an irradiation field.