Title of article
The digital radiographic and computed tomography imaging of two types of explosive devices
Author/Authors
Eduardo Galiano-Riveros، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
5
From page
861
To page
865
Abstract
Two well-established medical imaging methods, digital radiography (DR) and computed tomography (CT), were employed to obtain images of two types of explosive devices, model rocket engines and shotgun shells. The images were evaluated from an airport security perspective. In terms of geometrical shape, the detection probability of the explosive devices appears to be higher with DR imaging, but in terms of the actual explosive compounds in the devices, CT appears to offer a higher detection probability. DR imaging offers a low detection probability for the explosive powder in the shotgun shells, but a rather significant detection probability for the explosive propellant in the model rocket engines.
Journal title
Applied Radiation and Isotopes
Serial Year
2002
Journal title
Applied Radiation and Isotopes
Record number
541378
Link To Document