Title of article
A real-time positron monitor for the estimation of stack effluent releases from PET medical cyclotron facilities
Author/Authors
Bhaskar Mukherjee، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
7
From page
899
To page
905
Abstract
Large activities of short-lived positron emitting radiopharmaceuticals are routinely manufactured by modern Medical Cyclotron facilities for positron emission tomography (PET) applications. During radiochemical processing, a substantial fraction of the volatile positron emitting radiopharmaceuticals are released into the atmosphere. An inexpensive, fast response positron detector using a simple positron-annihilation chamber has been developed for real-time assessment of the stack release of positron emitting effluents at the Australian National Medical Cyclotron. The positron detector was calibrated by using a 3.0 ml (1.50 MBq) aliquot of 18FDG and interfaced to an industrial standard datalogger for the real-time acquisition of stack release data.
Keywords
scintillation detector , Stack effluent monitor , Positron monitor , Medical cyclotron , Positron emitting isotopes , positron emission tomography , positron annihilation
Journal title
Applied Radiation and Isotopes
Serial Year
2002
Journal title
Applied Radiation and Isotopes
Record number
541383
Link To Document