Title of article :
188Re-labeled hydroxyapatite particles for radiation synovectomy
Author/Authors :
K. Kothari، نويسنده , , S. Suresh، نويسنده , , H. D. Sarma، نويسنده , , V. Meera، نويسنده , , M. R. A. Pillai، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
A new procedure for labeling hydroxyapatite (HA) particles with 188Re for radiation synovectomy is described and standardized. The particles were labeled with 188Re in high yields (99%) in acidic medium. HA particle size remained unaffected by reaction conditions as checked by laser diffraction particle analyzer. 188Re-HA was found to be stable retaining 99% radiochemical purity after 4 days when stored in ascorbic acid solution (10 mg/ml, pH 5). Intra-articular injection in rats revealed not, vert, similar98% retention of 188Re-HA in the knee after 48-h pi.
Keywords :
188Re-HA , radiation synovectomy , 188Re , Hydroxyapatite
Journal title :
Applied Radiation and Isotopes
Journal title :
Applied Radiation and Isotopes