• Title of article

    An anticoincidence-shielded gamma-ray spectrometer for analysis of low level environmental radionuclides

  • Author/Authors

    Jong-Eun Byun، نويسنده , , Yun Ho Choi، نويسنده , , Seung Im Kwak، نويسنده , , Han Yull Hwang، نويسنده , , Kun-Ho Chung، نويسنده , , Geun Sik Choi، نويسنده , , Doo-Won Park، نويسنده , , Chang Woo Lee، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    5
  • From page
    579
  • To page
    583
  • Abstract
    We developed an ultralow-level background gamma-ray spectrometer, using active and passive shield devices at the same time. Cosmic-ray-induced background is suppressed by means of active shield devices consisting of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The observed background rate was 0.34 s−1 (=0.12 s−1 per 100 cm3 Ge volume) for energy regions between 50 and 3000 keV. The detection efficiency curve for 103 ml Marinelli beaker samples is obtained over all the energy regions. The advantages of the method are demonstrated by measuring the activity of 137Cs in powdered milk sample prepared without taking any chemical procedure. The MDA for 137Cs is estimated to be (17±1.7) mBq at a confidence level of 95% and it is about a factor of 10 lower than the MDA obtained from the previous cryostat assembly with 10-cm thick lead shielding.
  • Keywords
    Germanium spectrometer , Milk powder , Efficiency curve , Cosmic rays , Anticosmic shield , MDA