Half-life measurements of 87Rb by liquid scintillation counting
Author/Authors :
K. Kossert، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
6
From page :
377
To page :
382
Abstract :
The specific activity of natural 87Rb was measured by means of 4πβ liquid scintillation counting in a two-photomultiplier-tube spectrometer. 3H-efficiency tracing was used together with the CIEMAT/NIST method to obtain the detection efficiency. For this purpose a new parameterization of the shape factor for the third forbidden non-unique β-transition was performed. The hygroscopic behaviour of the salts used for sample preparation was studied. The half-life of 87Rb was found to be T1/2=4.967(32)×1010 y.
Keywords :
Half-life measurement , Beta spectrum , Liquid scintillation counting , CIEMAT/NIST method