Title of article :
Measurement of the residual radioactivity induced in the front foil of a target assembly in a modern medical cyclotron
Author/Authors :
R. G. O’Donnell، نويسنده , , L. Le?n Vintr?، نويسنده , , G. J. Duffy، نويسنده , , P. I. Mitchell، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
4
From page :
539
To page :
542
Abstract :
The levels of residual radioactivity induced in Havar® foils at the entrance of a high-pressure 18O-enriched water target used for the production of 18F− in a medical cyclotron with 16 MeV protons have been determined using high-resolution γ-ray spectrometry. Whole body and skin dose rates arising from exposure to these foils during their periodic replacement have been estimated. The results indicate that irradiated foils do not represent a significant radiological hazard for the cyclotron operating staff and that no waste disposal difficulties should be encountered after an appropriate ‘cooling’ period of 2 years.
Keywords :
Havar® foils , Activation products , Residual radioactivity , Medical cyclotron
Journal title :
Applied Radiation and Isotopes
Serial Year :
2004
Journal title :
Applied Radiation and Isotopes
Record number :
541640
Link To Document :
بازگشت