Title of article :
Freeze-drying applied to radioactive source preparation
Author/Authors :
J. de Sanoit، نويسنده , , B. Leprince، نويسنده , , Ch. Bobin، نويسنده , , J. Bouchard، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
In the framework of R&D studies for the improvement of radioactive source efficiencies prepared on thin films for 4πβ–γ coincidence counting, a comparative study on two drying methods has been undertaken in our laboratory (BNM-Laboratoire National Henri Becquerel, France). The standard method of evaporation at atmospheric pressure and a method based on freeze-drying using commercial equipment are compared. The preliminary results of this study obtained with 65Zn sources are presented and a significant improvement of the detection efficiencies to the electron emission for freeze-dried sources is shown. In the course of validation of this method, other radionuclides were studied and, up to now, the results confirm the better crystallization homogeneity achieved for freeze-dried sources.
Keywords :
freeze-drying , Source preparation , Radioactivity measurement