Title of article
Determination of hydrogen content in bulk samples using the neutron activation method
Author/Authors
R. D?czi، نويسنده , , M.A. Ali، نويسنده , , M. Fayez-Hassan، نويسنده , , J. Csikai، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2005
Pages
4
From page
137
To page
140
Abstract
The applicability of a new irradiation facility for bulk hydrogen analysis based on the activation method using thermal and epithermal neutrons has been tested for cylindrical samples of 8 cm diameter and 10 cm high. A definite correlation was found between the relative excess flux values, R and the total hydrogen contents, NH of the samples. Analytical expressions obtained for R vs. NH function indicate the possible use of this method even in the case of kg weight and liter sample dimensions. The large sample has a special advantage if the determination of the hydrogen concentration, CH is in question.
Keywords
Neutron moderation , Neutron flux determination , Hydrogen detection