Title of article :
Determination of the activity concentration of a 238Pu solution by the defined solid angle method utilizing a novel dual diaphragm-detector assembly
Author/Authors :
Julio C. Aguiar، نويسنده , , Eduardo Galiano، نويسنده , , Pablo Arenillas، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
5
From page :
229
To page :
233
Abstract :
The activity concentration of a 238Pu solution was measured by the determined solid angle method employing a novel dual diaphragm-detector assembly, which has been previously described. Due to the special requirements of the detector, a new type of source holder was developed, which consisted of sandwiching the radioisotope between two organic films called VYNS. It was experimentally demonstrated that the VYNS films do not absorb α particles, but reduce their energy by an average of 22 keV.A mean activity concentration for 238Pu of 359.10±0.8 kBq/g was measured.
Keywords :
238Pu activity concentration , Dual ? particle detector , VYNS film , VYNS absorption , VYNS attenuation
Journal title :
Applied Radiation and Isotopes
Serial Year :
2005
Journal title :
Applied Radiation and Isotopes
Record number :
542100
Link To Document :
بازگشت