Title of article :
Improvement of the tissue integration of a new modified polytetrafluoroethylene prosthesis: Mycro Mesh®
Author/Authors :
J. M. Bell?n، نويسنده , , J. Buj?n، نويسنده , , L. A. Contreras، نويسنده , , A. Carreras-San Mart?n، نويسنده , , A. Hernando، نويسنده , , F. Jurado and، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
7
From page :
1265
To page :
1271
Abstract :
We studied the behaviour of the different tissue interfaces formed on a new type of prosthesis used for the repair of abdominal wall defects, Mycro Mesh® (W. L. Gore and Ass., Flagstaff, AZ, USA), which consists of perforated layers of polytetrafluoroethylene (PTFE). In 20 New Zealand white rabbits, a full-thickness (except skin) 7 cm × 5 cm defect was created in the anterior abdominal wall. The defects were repaired with a prosthetic implant (Mycro Mesh®) that was placed in direct contact with abdominal viscera and subcutaneous tissue. At 14, 30, 60 and 90 d post-implantation, samples were obtained from the tissue interfaces formed between the prosthesis and subcutaneous tissue, visceral peritoneum and receptor tissue, respectively. Samples were studied by optical microscopy and scanning electron microscopy. The immunohistological study was made with RAM-11, a monoclonal antibody specific for rabbit macrophages. Tensile strength was measured with an Instron tensiometer using 2 cm wide strips obtained parallel to the shorter axis of the implant. Strips included the prosthesis and two anchor zones on the receptor tissue. Macroscopically, the prosthesis induced little adhesion formation on the visceral peritoneum interface. Microscopically, an organized neoperitoneum and abundant tissue formed on the subcutaneous interface. In the prosthesis perforations, bridges of tissue linked the peritoneal and subcutaneous sides. The macrophage response decreased significantly in intensity between day 14 and day 90 (Student-Newman-Keuls test, P = 0.01). Tensile strength increased significantly (Wilcoxon test, P < 0.05) at every study period. To conclude: the Mycro Mesh® prosthesis proved suitable for implantation in sites where it comes in contact with abdominal viscera and it provided good support for the formation of an organized neoperitoneum; the perforations in the prosthetic material improved implant integration; the macrophage response was not altered by the biomaterial and the tensile strength of the prosthesis increased as scar tissue formation and tissular integration of the prosthesis progressed.
Keywords :
Prosthetic patch , macrophages , abdominal wall repair , abdominal wall defects , PTFE
Journal title :
Biomaterials
Serial Year :
1996
Journal title :
Biomaterials
Record number :
542518
Link To Document :
بازگشت