Title of article
Surface characterization of C/Ti-6Al-4V coating treated with ion beam
Author/Authors
B. Demri، نويسنده , , M. Hage-Ali، نويسنده , , M. Moritz، نويسنده , , D. Muster، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1997
Pages
6
From page
305
To page
310
Abstract
Surface of titanium alloy (Ti-6Al-4V) has been modified by ion beam mixing of thin C film. X-ray photoelectron spectroscopy analysis showed that after mixing, the surface film consists essentially of a Ti compound containing (Ti, O and C), TiO2, Ti and C contamination. The composition of the surface modified film determined by Rutherford backscattering spectrometry is approximately Ti0.5O0.3C0.2 and its thickness is about 200 nm.
Keywords
Ion beam mixing , Titanium alloys , surface characterization