Title of article :
Equilibrium vapour pressure of mercury from dental amalgam under loading conditions
Author/Authors :
C. E. Moffitt، نويسنده , , D. M. Wieliczka، نويسنده , , P. Spencer، نويسنده , , R. Cole، نويسنده , , A. Wandera، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1998
Pages :
4
From page :
1319
To page :
1322
Abstract :
Earlier studies have failed to establish a consensus on the amount of mercury vapour released from dental amalgam restorations. The purpose of this study was to accurately and quantitatively measure the equilibrium mercury vapour pressure from dental amalgam. The vapour pressure was measured using a quartz crystal microbalance as a function of the load from 0–5.4 MPa. Auger spectra were collected of the as-formed and argon ion sputter cleaned dental amalgam surface. For the as-formed surface the mercury vapour density is zero with no load and increases to 0.6 μg m-3 at 5.4 MPa. Following cleaning the mercury, vapour density increased to a maximum value of 15 μg m-3. The Auger spectra of the as-formed surfaces were dominated by features associated with carbon and oxygen. These spectral results in concert with the mercury vapour density measurements indicate that the oxide film on the as-formed surfaces inhibited the release of mercury vapour. The results of this experiment provide an upper limit for the amount of mercury vapour released by dental amalgams. Under conditions simulating the oral cavity this value would be reduced by oxides that form on the surface of dental amalgam restorations.
Keywords :
Surface analysis , Mercury vapour , mercury , Dental amalgam
Journal title :
Biomaterials
Serial Year :
1998
Journal title :
Biomaterials
Record number :
543034
Link To Document :
بازگشت