Title of article :
Surface modification using silanated poly(ethylene glycol)s
Author/Authors :
Seongbong Jo، نويسنده , , Kinam Park، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
12
From page :
605
To page :
616
Abstract :
Surface-grafted poly(ethylene glycol) (PEG) molecules are known to prevent protein adsorption to the surface. The protein-repulsive property of PEG molecules are maximized by covalent grafting. We have synthesized silanated monomethoxy-PEG (m-PEG) for covalent grafting of PEG to surfaces with oxide layers. Two different trialkoxysilylated PEGs were synthesized and characterized. The first trialkoxysilylated PEG was prepared by direct coupling of m-PEG with 3-isocyanatopropyltriethoxysilane through a urethane bond (silanated PEG I). The other silanated PEG (silanated PEG II) containing a long hydrophobic domain between PEG and a silane domain was prepared by reacting m-PEG with 1,6-diisocyanatohexane and 10-undecen-1-ol in sequence before silylation with 3-mercaptopropyl trimethoxysilane. Silanated PEGs I and II were grafted onto glass, a model surface used in our study. The PEG-grafted glass surfaces were characterized by contact angle, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). Although contact angle did not change much as the bulk concentration of silanated PEG used for grafting increased from 0.1 to 20 mg/ml for both PEGs I and II, the surface atomic concentrations from XPS measurements showed successful PEG grafting. Surface PEG grafting increased concentration of surface carbon but decreased silicone concentration. The high resolution C1s spectra showed higher ether carbon with lower hydrocarbon compositions for the PEG-grafted surfaces compared to the control surface. AFM images showed that more PEG molecules were grafted onto the surface as the bulk concentration used for grafting was increased. AFM images of the dried surfaces showed that the surfaces were not completely covered by PEG molecules. After hydration, however, the surface appears to be covered completely probably due to the hydration of the grafted PEG chains. Glass surfaces modified with silanated PEGs reduced fibrinogen adsorption by more than 95% as compared with the control surface. Silanated PEGs provides a simple method for PEG grafting to the surface containing oxide layers.
Keywords :
Poly(ethylene oxide) , Silanated PEG , Contact angle , X-ray photoelectron spectroscopy , Surface grafting , Atomic force microscopy
Journal title :
Biomaterials
Serial Year :
2000
Journal title :
Biomaterials
Record number :
543478
Link To Document :
بازگشت