Title of article :
Mixing in Process Vessels Used in Biopharmaceutical Manufacturing
Author/Authors :
Slater، Nigel K. H. نويسنده , , Ram، Kripa نويسنده , , Vickroy، T. Bruce نويسنده , , Lamb، Keith A. نويسنده , , Dennis، John S. نويسنده , , Duffy، Louise E. نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
-243
From page :
244
To page :
0
Abstract :
The use of nonbaffled vessels for mixing applications is becoming common in the biopharmaceutical industry but is not sufficiently well studied. Orientation of the impellers off-centered and/or at an angle is necessary to enhance mixing and eliminate swirling that would result without a baffle in a standard tank. This study focuses on characterizing mixing in vessels with the hydrofoil axial flow impellers mounted offcenter at 10° to the vertical. Geometrically similar vessels ranging from 100 to 5000 L working volume were used in this study. Mixing performance was successfully correlated to vessel geometric factors.