• Title of article

    Measurement of Poissonʹs ratio of dental composite restorative materials

  • Author/Authors

    Sew Meng Chung، نويسنده , , Adrian U. Jin Yap، نويسنده , , Wee Kiat Koh، نويسنده , , Kuo Tsing Tsai، نويسنده , , Chwee Teck Lim، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    6
  • From page
    2455
  • To page
    2460
  • Abstract
    The aim of this study was to determine the Poisson ratio of resin-based dental composites using a static tensile test method. Materials used in this investigation were from the same manufacturer (3M ESPE) and included microfill (A110), minifill (Z100 and Filtek Z250), polyacid-modified (F2000), and flowable (Filtek Flowable [FF]) composites. The Poisson ratio of the materials were determined after 1 week conditioning in water at 37°C. The tensile test was performed with using a uniaxial testing system at crosshead speed of 0.5 mm/min. Data was analysed using one-way ANOVA/post-hoc Scheffeʹs test and Pearsonʹs correlation test at significance level of 0.05. Mean Poissonʹs ratio (n=8) ranged from 0.302 to 0.393. The Poisson ratio of FF was significantly higher than all other composites evaluated, and the Poisson ratio of A110 was higher than Z100, Z250 and F2000. The Poisson ratio is higher for materials with lower filler volume fraction.
  • Keywords
    Poisson’s ratio , Dental restorative materials , composite resins , elastic properties , elastic constants
  • Journal title
    Biomaterials
  • Serial Year
    2004
  • Journal title
    Biomaterials
  • Record number