• Title of article

    Self-curing controlled release systems for steroids. Application of prednisolone-based polymeric systems to ear diseases

  • Author/Authors

    Mar Fernandez، نويسنده , , Juan Parra، نويسنده , , Blanca Vazquez، نويسنده , , Antonio Lopez-Bravo، نويسنده , , Julio San Rom?n، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    8
  • From page
    3311
  • To page
    3318
  • Abstract
    An injectable delivery system for prednisolone has been prepared based on a self-curing formulation comprised of poly(methyl methacrylate) particles and hydroxyethyl methacrylate as monomer. The polymerisation reaction was initiated by the redox system 4,4′-bis (dimethylaminobenzydrol)/benzoyl peroxide (BZN/BPO) and followed at 25 °C by measuring the time–temperature profile. A maximum temperature of 53 °C and a setting time of 15 min were obtained, calculated according to standard specifications. The swelling of the cured system was studied in phosphate-buffered saline (PBS) at 37 °C giving a hydration degree at equilibrium of 20%. The swelling kinetics fitted a fickian behaviour at the initial stages of the experiments, with a diffusion coefficient of 0.72×10−7 cm2/s. The release of the drug was sustained from the beginning without an initial drug burst. The study of the wettability showed a rather hydrophilic character of the surface of the loaded system, and the biocompatibility evaluated through MTT assay revealed the absence of cytotoxicity due to the release of toxic substances.
  • Keywords
    prednisolone , Ear disease , DRUG DELIVERY , PMMA/PHEMA
  • Journal title
    Biomaterials
  • Serial Year
    2005
  • Journal title
    Biomaterials
  • Record number