• Title of article

    Monte Carlo studies of the Tunisian gamma irradiation facility using GEANT4 code

  • Author/Authors

    O. Kadri، نويسنده , , F. Gharbi، نويسنده , , K. Farah، نويسنده , , K. Mannai، نويسنده , , A. Trabelsi، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    8
  • From page
    170
  • To page
    177
  • Abstract
    This paper describes a complete Monte Carlo study of the Tunisian gamma irradiation facility (CNSTN) using the GEANT4 CERNʹs code. The work focused on the optimization of the absorbed dose distribution inside the irradiation cell, with and without product. For this purpose, 32 different points at the middle plane of the source rack, 29 positions along Z axis and 7 critical points, were carried out using PMMA dosimeters. Then, to achieve a given bulk density, boxes loaded with “dummy” product were used. Simulated and experimental results are compared and good agreement is observed. It is shown that Monte Carlo simulation improves process understanding, predicts absorbed dose distributions and calculates dose uniformity within product.
  • Keywords
    Monte Carlo , Gamma irradiation facility , Geant4 , dose rate
  • Journal title
    Applied Radiation and Isotopes
  • Serial Year
    2006
  • Journal title
    Applied Radiation and Isotopes
  • Record number