Title of article :
Distortion of neutron field during mice irradiation at Kinki University Reactor UTR-KINKI
Author/Authors :
Satoru Endo، نويسنده , , Kenichi Tanaka، نويسنده , , Kazuo Fujikawa، نويسنده , , Tetsuo Horiguchi، نويسنده , , Tetsuo Itoh، نويسنده , , Gerard Bengua، نويسنده , , Taisei Nomura، نويسنده , , Masaharu Hoshi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
A dosimetry study of mice irradiation at the Kinki University nuclear reactor (UTR-KINKI) has been carried out. Neutron and gamma-ray doses at the irradiation port in the presence of 0, 1, 2, 4 and 6 mice were measured using the paired chamber method. The results show that neutron dose is reduced with increasing numbers of mice. In the six-mice irradiation condition, neutron dose is about 15% smaller compared to a case where no mice were placed in the irradiation port.
To investigate the distortion of the neutron spectrum during mice irradiation at UTR-KINKI, a Monte Carlo calculation using the MCNP4C code has been carried out. The measured variation in dose with respect to the total mouse mass was closely reproduced by the calculation results for neutron and gamma-ray dose. Distortion of the neutron spectrum was observed to occur between 1 keV and 1 MeV.
Keywords :
neutron spectrum , Mice irradiation , dosimetry , Reactor radiation , UTR-KINKI
Journal title :
Applied Radiation and Isotopes
Journal title :
Applied Radiation and Isotopes