Title of article :
Application of alpha track registration technique for plutonium estimation in bioassay samples
Author/Authors :
Pramilla D. Sawant، نويسنده , , S.P. Prabhu، نويسنده , , P.C. Kalsi، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
Bioassay monitoring is carried out for occupational workers handling plutonium (Pu) in nuclear facilities. In India, presently Pu estimation in bioassay samples is done by alpha spectrometry. The minimum detectable activity (MDA) of alpha spectrometry is 0.5 mBq for a counting period of 1 day. To reduce the load of sample counting on alpha spectrometry, an alternative method based on alpha track registration in solid state nuclear track detectors (SSNTDs) is developed in the present paper. For this purpose, few urine samples of normal subjects spiked with known amounts of Pu in the range of 0.5–5.5 mBq were exposed to CR-39 SSNTDs. The total number of alpha tracks seen in the CR-39 films of the sample and the standard were used to calculate the amount of Pu in the sample. The results of alpha track registration technique were also compared with that obtained by the well-established alpha spectrometry and were found to agree well within ±30%. The minimum amount of Pu that can be analyzed by this method is 0.18 mBq for an exposure period of 45 days.
Keywords :
Bioassay samples , plutonium , Alpha track technique , Alpha spectrometry , SSNTDs
Journal title :
Applied Radiation and Isotopes
Journal title :
Applied Radiation and Isotopes