Title of article
End-to-side microvascular anastomosis using an external metal ring
Author/Authors
S. Karamürsel، نويسنده , , A. Kayikcioglu، نويسنده , , T. Safak، نويسنده , , A. Keçik، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
4
From page
423
To page
426
Abstract
Enthusiasm for developing safer and faster anastomotic techniques and complementary devices continues. We report on a new microvascular end-to-side anastomosis technique using a silver ring around the anastomotic circumference. The purpose of this study was to compare the effectiveness of this technique with conventional end-to-side vessel anastomosis.
Forty Sprague-Dawley rats were divided into two groups. Twenty rats were used to assess the external ring method in end-to-side anastomosis between carotid arteries and anterior jugular veins and the remaining 20 formed the control group with conventional end-to-end anastomosis.
The anastomosis time was 26.4 min for standard suture anastomosis and 18.4 min for the external ring technique (P< 0.01). Patency was 95% with standard technique and 100% using the external ring (P> 0.05). The external ring technique of end-to-side microvascular anastomosis is a safe and reliable method and may reduce the operation time. Its clinical applicability should be further evaluated.
Keywords
external metal ring , end-to-side anastomosis , anastomosis time , anastomotic patency. , experimental study , : microvascular anastomosis
Journal title
Journal of Plastic , Reconstructive and Aesthetic Surgery
Serial Year
2000
Journal title
Journal of Plastic , Reconstructive and Aesthetic Surgery
Record number
594712
Link To Document