Title of article :
Appropriateness of MRI scanning in the detection of ruptured implants used for breast reconstruction
Author/Authors :
Adam Topping، نويسنده , , Christopher George، نويسنده , , Geoffrey Wilson and Barry L. Stoddard، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
This case report highlights the problems associated with ruptured silicone breast implants used for breast reconstructive purposes. The patient originally presented with vague symptoms and signs to her GP and was extensively investigated over a period of years for left-sided chest/abdominal pain. Two separate scanning modalities were used prior to her being seen by either of the main authors and although none were employed specifically to assess for implant rupture, neither detected any free silicone around the hemithorax. The authors suggest that patients who have undergone breast reconstruction with a silicone implant may present in a manner not suggestive of implant damage. In such cases, where the silicone can extend over larger anatomical distances and where side-effects can be damaging the investigation of choice should be MRI scanning which has a greater accuracy for detecting free silicone and defining the extent of spread.
Keywords :
Breast reconstruction , implant rupture , accuracy , Silicone implants , scanning modalities
Journal title :
Journal of Plastic , Reconstructive and Aesthetic Surgery
Journal title :
Journal of Plastic , Reconstructive and Aesthetic Surgery