Title of article :
Troglitazone reduces neointimal tissue proliferation after coronary stent implantation in patients with non–insulin dependent diabetes mellitus: A serial intravascular ultrasound study  
Author/Authors :
Tsutomu Takagi، نويسنده , , Takashi Akasaka، نويسنده , , Atsushi Yamamuro، نويسنده , , Yasuhiro Honda، نويسنده , , Takeshi Hozumi، نويسنده , , Shigefumi Morioka، نويسنده , , Kiyoshi Yoshida، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
7
From page :
1529
To page :
1535
Abstract :
OBJECTIVES The aim of the present study was to determine whether troglitazone reduces neointimal tissue proliferation after coronary stent implantation in patients with non–insulin dependent diabetes mellitus (NIDDM). BACKGROUND Increased in-stent restenosis in patients with diabetes mellitus is due to accelerated neointimal tissue proliferation after coronary stent implantation. Troglitazone inhibits intimal hyperplasia in experimental animal models. METHODS We studied 62 stented lesions in 52 patients with plasma glucose levels (PG) ≥11.1 mmol/liter at 2 h after 75 g oral glucose load. The study patients were randomized into two groups: the troglitazone group of 25 patients with 29 stents, who were treated with 400 mg of troglitazone, and the control group of 27 patients with 33 stents. All patients underwent oral glucose tolerance tests before and after their six-month treatment period. The sum of PG (ΣPG) and the sum of insulin levels (ΣIRI) were measured. Serial (postintervention and at six-month follow-up) intravascular ultrasound studies were performed. Cross-sectional images within stents were taken at every 1 mm, using an automatic pullback. Stent areas (SA), lumen areas (LA), and intimal areas (IA = SA − LA) were measured and averaged over a number of selected image slices. The intimal index was calculated as intimal INDEX = averaged IA/averaged SA × 100%. RESULTS There were no differences between the two groups before treatment in ΣPG (31.35 ± 3.07 mmol/liter vs. 32.89 ± 4.87 mmol/liter, respectively, P = 0.2998) and ΣIRI (219.6 ± 106.2 mU/liter vs. 209.2 ± 91.6 mU/liter, respectively, P = 0.8934). However, reductions in ΣPG at the six-month follow-up in the troglitazone group were significantly greater than those in the control group (−21.4 ± 8.8% vs. −4.5 ± 7.4%, respectively, p < 0.0001). Likewise, decreases in ΣIRI were greater in the troglitazone-treated group (−31.4 ± 17.9% vs. −1.9 ± 15.1%, respectively, p < 0.0001). Although, there were no differences between the two groups in SA at postintervention (7.4 ± 2.2 mm2 vs. 7.3 ± 1.7 mm2, respectively, P = 0.9482) and at follow-up (7.3 ± 2.3 mm2 vs. 7.3 ± 1.8 mm2, respectively, P = 0.2307), the LA at follow-up in the troglitazone group was significantly greater than that in the control group (5.3 ± 1.7 mm2 vs. 3.7 ± 1.7 mm2, respectively, P = 0.0002). The IA at follow-up in the troglitazone group was significantly smaller than that in the control group (2.0 ± 0.9 mm2 vs. 3.5 ± 1.8 mm2, respectively, p < 0.0001). This was also true for intimal index (27.1 ± 11.5% vs. 49.0 ± 14.4%, respectively, p < 0.0001). CONCLUSIONS Serial intravascular ultrasound assessment shows that administration of troglitazone reduces neointimal tissue proliferation after coronary stent implantation in patients with NIDDM.
Keywords :
LA , VSMC , cross-sectional lumen areas , Vascular smooth muscle cell , LDL , low-density lipoprotein , DM , MLD , diabetes mellitus , minimal lumen diameter , HDL , NIDDM , high-density lipoprotein , non-insulin dependent diabetes mellitus , IA , OGTT , IGT , PDGF , Impaired glucose tolerance , platelet-derived growth factor , IRI , PG , immunoreactive insulin level , plasma glucose level , IVUS , SA , intravascular ultrasound , cross-sectional stent areas , intimal areas , Oral glucose tolerance test
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2000
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :
596173
Link To Document :
بازگشت