Title of article :
Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves
Author/Authors :
Hisashi Masugata، نويسنده , , Barry Peters، نويسنده , , Stephane Lafitte، نويسنده , , G. Monet Strachan، نويسنده , , Koji Ohmori، نويسنده , , Anthony N. DeMaria، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
OBJECTIVES
The present study examined the ability of real-time myocardial contrast echocardiography (MCE) to delineate abnormalities produced by graded coronary stenoses and to correlate signal intensity (SI) parameters derived from destruction/refilling curves with regional myocardial blood flow (MBF) and contractile function.
BACKGROUND
Recent technological advances have enabled myocardial opacification by MCE to be achieved during real-time imaging.
METHODS
In eight open-chest dogs, we created LAD occlusion and graded stenoses that were either flow-limiting at rest (FLS) or reduced adenosine hyperemia (non-flow-limiting at REST = NFLS). Myocardial contrast echo used Optison infusion and low-energy real-time power pulse inversion imaging. High-energy FLASH frames destroyed bubbles every 15 cardiac cycles. Myocardial SI-versus-time plots were fitted to a one-exponential function to obtain the rate of SI rise (b) and peak SI in the last frame.
RESULTS
Dyssynergy was not observed during any NFLS, but perfusion abnormalities were. Visual detection of decreased opacification was possible with severe NFLS and FLS. b demonstrated a significant reduction with severe NFLS and near significant with moderate NFLS; peak SI did not. All exponential parameters were significantly decreased with FL stenosis and occlusion. The MBF ratio in LAD/LCx beds (fluorescent microspheres) correlated with b (r = 0.79) and the product of the peak SI and b (r = 0.80).
CONCLUSIONS
In an open-chest dog model, parameters derived from microbubble refilling of the imaging field by real-time MCE correlate well with myocardial blood flow and can identify coronary stenosis.
Keywords :
MCE , non-flow-limiting stenosis , ECG , PPI , left circumflex coronary artery , wall thickening , LV , flow-limiting stenosis , Regions of interest , MBF , Electrocardiogram , power pulse inversion , LCx , WT , NFLS , LAD , Si , Left ventricular , left anterior descending coronary artery , Signal intensity , FLS , ROI , myocardial blood flow , myocardial contrast echocardiography