Title of article :
Specificity of Doppler echocardiography for the assessment of changes in valvular regurgitation: comparison of side-by-side versus serial interpretation
Author/Authors :
Neil J. Weissman، نويسنده , , Julio A. Panza، نويسنده , , John F. TigheJr.، نويسنده , , Susan T. Perras، نويسنده , , Harvey Kushner، نويسنده , , John S. Gottdiener، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Abstract :
OBJECTIVES
We sought to determine the specificity of two different methods for assessing change in aortic (AR), mitral (MR) and tricuspid (TR) valvular regurgitation.
BACKGROUND
Echocardiographic imaging with Doppler is the standard noninvasive diagnostic tool for assessing valvular structure and function. Change can be assessed using either independent evaluations (serial) or using a side-by-side comparison.
METHODS
Subjects were from the placebo arm of a randomized, double-blind, clinical trial. Three echocardiograms over 10 months were performed. An initial and three-month echocardiogram were read as independent groups, blinded to all parameters except sequence. The initial and 10-month echocardiograms were read side-by-side, blinded to all parameters including sequence.
RESULTS
Two hundred nineteen predominantly healthy, obese, white, middle-aged women had initial and three-month echocardiograms (acquisition interval 105 ± 28 days) evaluated by the serial method (mean 167 ± 61 days between interpretations). The same subjects had the initial and 10-month studies (acquisition interval 303 ± 27 days) compared side-by-side. The specificity of the serial versus side-by-side method for determining change in MR grade was 55.8% versus 93.2% (p < 0.001); TR: 63.8% versus 97.6% (p < 0.001) and AR: 93.7% versus 97.6 (p = 0.08). Notably, most of the change occurred in a range (none versus physiologic/mild) that has limited clinical significance. Furthermore, the percentage of echocardiograms interpreted as nonevaluable was lower with the side-by-side method for MR (5.0% vs. 16.0%, P = 0.06), TR (4.6% vs. 15.5%, p < 0.001) and AR (4.1% vs. 12.3%, P = 0.002).
CONCLUSIONS
The side-by-side method of assessing change in valvular regurgitation appears to be the more reliable method with a higher specificity and minimal data loss.
Keywords :
AR , aortic regurgitation , MR , tricuspid regurgitation , mitral regurgitation , TR
Journal title :
JACC (Journal of the American College of Cardiology)
Journal title :
JACC (Journal of the American College of Cardiology)